GREEN CHOICE
Technical guides to the Siemens products in our catalogue
Each range has a main guide covering series, order number roots and services, plus detailed guides on the individual series.
How to find your way around the catalogue
Siemens updates
End of life, successor products and technical notes, explained for those whose plant is still running.
Browse by range
Choose the range used in your plant: the number shows how many guides are available.
Automation and CNC
Controllers, CNC and power suppliesSIMATIC
PLCs, distributed I/O, HMI panelsSINUMERIK
CNC numerical controlsSITOP
Power suppliesDrives
Inverters, converters and controllersSINAMICS
Converters and drivesSIMODRIVE
Machine tool drivesSIMOVERT MASTERDRIVE
DrivesMotors, motion control and starting
Motors, motion control, starting and protectionSIMOTION
Motion control systemsSIRIUS
Contactors, motor protection, soft startersOther Siemens families
Industrial communication, industrial PCs, process control and versions for harsh environments.
Other Siemens products
Smaller families in our catalogue: versions for harsh environments, drive control, photovoltaic inverters, instrumentation and legacy systemsSIMATIC NET and SCALANCE
Communication processors and industrial network switchesSIPLUS
Versions of SIMATIC, SITOP and SINAMICS for harsh environmentsSIMATIC C7
Compact controllers with operator panelSiemens manuals and documentation
Official manuals, FAQs, data sheets and certificates, always up to date on the Siemens portal.
- Details
Siemens SIRIUS: contactors, motor protection, soft starters and starters
SIRIUS is the Siemens range of low-voltage switching and protection components: contactors, auxiliary relays, motor protection circuit breakers, overload relays, soft starters, starters and command devices. It is not a SIMATIC series: SIRIUS devices work in the control cabinet alongside PLCs and inverters, but they have their own part numbers, functions and replacement logic.
⚙️ 3RW soft starters
| Root | Components |
| 3RW30 | Compact soft starters, for example 7.5 kW at 400 V |
| 3RW40 | Soft starters in sizes S0 and S6, for example 11 kW at 400 V and 75 kW at 460 V |
| 3RW47 | Spare part for soft starters |
| Go to the catalogue | |
⚙️ Contactors, relays and motor protection
| Root | Components |
| 3RT | Power contactors, for example AC-3 11 kW at 400 V |
| 3RH | Auxiliary relays (auxiliary contactors), for example 4 NO contacts |
| 3RV | Motor protection circuit breakers, for example size S00 class 10 |
| 3RU | Overload relays, for example setting range 5.5–8 A |
| Go to the catalogue
3RT1026-1BB40 – AC-3 contactor 11 kW | |
⚙️ Starters and command devices
| Root | Components |
| 3RK1301 | DS1-x motor starters for ET 200S distributed I/O, with adjustable current range |
| 3SB3 | Command and signalling devices: compact units and actuators with lock |
| Go to the catalogue | |
⚠️ Typical faults
- worn or welded contacts after many switching operations or high inrush currents
- contactor coils open or damaged by incorrect control voltages
- soft starter power stages damaged by overloads or too frequent starts
- overheating due to insufficient ventilation in the cabinet
- repeated tripping of the protections due to a current setting not suited to the motor
🛠️ E-Repair services for SIRIUS
As an Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in the certified E-Repair in-house laboratory, with diagnosis and intervention where technically possible.
♻️ Refurbishment with replacement of components subject to wear and functional testing according to the agreed scope.
🚚 Advance supply of a refurbished or new product, if available in stock and after a compatibility check.
🛠️ On-site and remote technical support for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can a SIRIUS 3RW soft starter be repaired?
In many cases, yes: the 3RW part numbers in the catalogue are listed as repairable. Send us the full part number from the rating plate and a description of the fault, so we can assess whether repair or replacement is the better option.
✔️ What is the difference between a 3RV and a 3RU?
The 3RV is a circuit breaker that protects the motor against short circuit and overload. The 3RU is an overload relay that works together with the contactor. Before replacing them, always check the current setting range.
✔️ Why do 3RK1301 starters also appear in the SIMATIC guides?
They are motor starters designed for SIMATIC ET 200S distributed I/O: they are mounted in the ET 200S station, so you will also find them in the dedicated guide.
📚 Further reading
👉 SIMATIC ET 200S · 👉 SIMATIC E-Repair services · 👉 SIMOTICS motors · 👉 SITOP power supplies
ℹ️ The information is general and indicative. Before purchase, installation or commissioning, check the data in the official Siemens documentation or contact E-Repair.
🔗 Most requested part numbers
Some product pages from the E-Repair catalogue for the series in this guide:
- 3RK1301-0HB00-0AA2 – DS1-X FOR ET 200S ELECTROMECHANICS LINE STARTER EXPANDABLE…
- 3RW3018-1BB14 – SOFT STARTER 400V 7,5KW 17,6A AUS 220V
- 3RW4755-6SB40 – REPAIR PART
- 3SB3500-4ED01 – ACTUATOR SAFETY LOCK, FLAT
- Details
Siemens SINAMICS S120: the modular drive system, components and formats
SINAMICS S120 is the Siemens modular drive system for single-axis and multi-axis applications: machine tools, packaging lines, printing, handling and, in the larger sizes, process plants. Instead of a single inverter, the S120 is made up of separate modules that work together: a Control Unit that handles closed-loop control, a Line Module that supplies the DC link and one or more Motor Modules that drive the motors. The modules communicate with each other over DRIVE-CLiQ.
The same system comes in three formats: Booksize for low and medium power, Chassis for high power and Cabinet Modules, i.e. modules already mounted in a cabinet. This guide is the general map: for each group you will find the part number roots and the link to the detailed guide.
⚙️ Control Units and system components
| Root | Components |
| 6SL3040 | Control Units CU320, CU320-2, CU310 and CU310-2 (PROFIBUS or PROFINET), CUA31 and CUA32 adapters. The root is shared with the CU305 Control Units of SINAMICS S110 and with the G130 Control Unit kit |
| 6SL3054 | S120 CompactFlash memory cards, with or without performance expansion; the root also includes the S110 and G120 cards |
| 6SL3055 | Encoder Sensor Modules (SMC20, SMC30, SME20, SME25, SME120, SME125), TM31 Terminal Module and AOP30 operator panel |
| 6SL3100 | Control Supply Module, Active Interface Module, braking and capacitor modules, resistors, Voltage Clamping Module |
| Go to the catalogue
6SL3040-1MA00-0AA0 – Control Unit CU320-2 DP | |
📖 Detailed guides: S120 control modules · Sensor Module, Terminal Module, DRIVE-CLiQ and memory card
⚙️ Booksize format: Line Modules and Motor Modules
| Root | Components |
| 6SL3130, 6SL3131, 6SL3136, 6SL3430 | 380–480 V three-phase supply Line Modules: Smart Line Module, Active Line Module and Basic Line Module |
| 6SL3120 | Single Motor Modules and Double Motor Modules with 600 V DC input, also in the Value version |
| 6SL3121, 6SL3126, 6SL3420 | Other design variants of 600 V DC Single and Double Motor Modules |
| 6SL3111 | Combi Power Module, supply and several axes in a single unit |
| Go to the catalogue | |
📖 Detailed guides: S120 Line Modules · S120 Motor Modules
⚙️ Chassis format
| Root | Components |
| 6SL3320, 6SL3321 | Chassis Single Motor Modules with DC input, in the 510–720 V DC and 675–1035 V DC ranges; Chassis-2 Motor Modules |
| 6SL3330, 6SL3335 | Chassis Line Modules: Smart, Basic and Active Line Modules, for 380–480 V and 500–690 V networks |
| Go to the catalogue | |
⚙️ Cabinet Modules
| Root | Components |
| 6SL3720 | S120 Cabinet Modules: in the catalogue they have a generic description, the module type is identified by the full part number |
| 6SL3730 | Line Modules in cabinet: Basic and Active Line Modules |
| 6SL3700 | Auxiliary cabinet modules: Line Connection Module, Central Braking Module and auxiliary supply. The root also includes some switches and fuses for SINAMICS V50 |
| Go to the catalogue | |
📖 Detailed guide: S120 Cabinet Modules 6SL3720 6SL3730
⚠️ Typical faults
- worn cooling fans, with temperature alarms and protection tripping
- aged DC-link capacitors, especially on modules left out of service for a long time
- power stages damaged by short circuits on the motor or cables
- DRIVE-CLiQ communication errors caused by cables, connectors or interface boards
- damaged memory cards or a configuration that the Control Unit can no longer read
- control electronics damaged by overvoltage, humidity or dirt in the cabinet
🛠️ E-Repair services for SINAMICS S120
As an Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in the certified E-Repair in-house laboratory, with diagnosis and intervention where technically possible.
♻️ Refurbishment with replacement of components subject to wear and functional testing according to the agreed scope.
🚚 Advance supply of a refurbished or new product, if available in stock and after a compatibility check.
🛠️ On-site and remote technical support for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can a single S120 module be replaced without changing the whole drive?
Yes, the system is modular and every Control Unit, Line Module or Motor Module has its own part number. Before replacement, check the full part number including the version, because the drive configuration is based on the installed modules.
✔️ What should I do with the CompactFlash card when the Control Unit goes for repair?
The memory card contains the firmware and the drive configuration: keep a copy and state in your request whether the card is shipped together with the Control Unit or stays in the machine.
✔️ How can I tell from the part number whether a module is Booksize, Chassis or Cabinet?
In most cases the root tells you: 6SL31 roots correspond to Booksize modules, 6SL33 to Chassis and 6SL37 to Cabinet Modules. If in doubt, send us the full part number from the rating plate.
📚 Further reading
👉 SINAMICS E-Repair services · 👉 SINAMICS S150 · 👉 SINAMICS S110 · 👉 Spare parts for chassis units · 👉 Mixed SIMODRIVE and SINAMICS systems
ℹ️ The information is general and indicative. Before purchase, installation or commissioning, check the data in the official Siemens documentation or contact E-Repair.
🔗 Most requested part numbers
Some product pages from the E-Repair catalogue for the series in this guide:
- 6SL3040-0JA00-0AA0 – SINAMICS S110 CONTROL UNIT CU305 DP WITH PROFIBUS INTERFACE…
- 6SL3054-0CD01-1AA0 – SINAMICS S120 CompactFlash card with firmware option Performance…
- 6SL3055-0AA00-2TA0 – SINAMICS S120 TERMINAL BOARD TB30 FOR CONTROL UNIT CU320 AND…
- 6SL3100-0BE21-6AB0 – SINAMICS S120 ACTIVE INTERFACE MODULE FOR 16KW ACTIVE LINE MODULE…
- 6SL3111-4VE21-6EA1 – SINAMICS S120 Combi Power Module input: 3AC 400V, 16 kW…
- 6SL3120-1SE11-7UA0 – SINAMICS S120 CONVERTER POWER MODULE PM340 INPUT: 3AC 380-480V…
- Details
Siemens SIMOTICS M: spindle motors 1PH4, 1PH6, 1PH7 and 1PH8
1PH series motors are Siemens motors for main spindles and power drives: lathes, machining centres, but also printing, paper, extrusion machines and winders. Today they are part of the SIMOTICS M range.
The E-Repair catalogue covers about 27 part numbers of 1PH motors and related accessories.
⚙️ Series in the catalogue
| Series | Features | Part numbers |
| 1PH4 | Water-cooled AC spindle motors, for 600 V DC link, for example 15 kW and 46 kW | 2 |
| 1PH6 | AC spindle motors with separate ventilation, for example 9 kW | 2 |
| 1PH7 | SIMOTICS M compact asynchronous motors, for example from 5.5 kW to 37 kW; encoder kits | 12 |
| 1PH8 | SIMOTICS M compact motors, asynchronous and synchronous, for example from 2.8 kW to 74 kW; spare fans | 11 |
👉 1PH4167-4NF26-Z – 46 kW water-cooled spindle motor
👉 1PH7131-2HF03-0BA3 – SIMOTICS M 1PH7 11 kW
👉 1PH8137-2FL12-0BA1 – SIMOTICS M 1PH8 synchronous 48.4 kW
👉 Search the catalogue: 1PH4 · 1PH6 · 1PH7 · 1PH8
⚠️ Typical faults
- worn bearings, with noise, vibration and overheating
- faulty encoders or speed sensors
- windings damaged by overloads or coolant ingress
- inefficient fans or water cooling circuits
Many apparently electrical faults actually depend on the encoder or the bearings: a complete diagnosis avoids unnecessary replacements.
🛠️ E-Repair services for SIMOTICS M 1PH motors
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can a spindle motor be repaired?
Yes, in most cases: bearings, encoders, fans and, when necessary, windings. E-Repair assesses the repair after diagnosis.
✔️ Is recommissioning needed after replacing the encoder?
Often yes, in particular for synchronous motors: the rotor position must be checked with the drive.
✔️ What is needed for the diagnosis?
The full part number from the motor rating plate, the connected drive and a description of the fault.
📚 Further reading
👉 SIMOTICS range · 👉 SIMOTICS S 1FK6 and 1FK7 · 👉 SIMODRIVE 611 · 👉 SINAMICS S120 motor modules
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
- Details
Siemens SITOP: UPS and add-on modules (roots 6EP19 and 6EP41)
In addition to power supplies, the SITOP range includes modules that protect and distribute the 24 V: DC UPS units that keep PLCs and PCs powered during mains outages, and add-on modules for diagnostics, selectivity and output redundancy.
The E-Repair catalogue covers about 34 part numbers for these modules.
⚙️ Product lines in the catalogue
| Root | Content | Part numbers |
| 6EP1931 | DC UPS modules with battery charger for lead-acid batteries, for example 10, 15 and 40 A | 15 |
| 6EP1933 | UPS500S and UPS500P, maintenance-free, with capacitor storage | 2 |
| 6EP1935 | UPS501S expansion modules for UPS500S | 7 |
| 6EP1961 | SITOP select (multi-channel diagnostics), PSE200 modules and buffer modules | 7 |
| 6EP4131, 6EP4134, 6EP4136 | UPS1100 (battery modules) and UPS1600 | 3 |
👉 6EP1931-2DC01 – DC UPS module with battery charger
👉 6EP1961-2BA00 – SITOP select diagnostic module
👉 6EP4136-3AB00-0AY0 – SITOP UPS1600 20 A
👉 Search the catalogue: 6EP1931 · 6EP1935 · 6EP1961
⚠️ Typical faults
- exhausted batteries or degraded storage capacitors, with reduced backup time
- faulty charging circuits
- switchover not taking place when the mains fails
- diagnostic module channels that do not switch or report non-existent faults
A UPS that does not switch over is often only discovered at the first blackout: periodically checking backup time and battery condition avoids nasty surprises.
🛠️ E-Repair services for SITOP UPS and modules
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can UPS batteries be repaired?
Batteries are consumables and are replaced; the UPS module itself, however, can often be repaired.
✔️ What is the difference between UPS500S and battery DC UPS?
The UPS500S stores energy in capacitors and requires no battery maintenance; DC UPS modules use lead-acid batteries with longer backup time.
✔️ What is needed for the diagnosis?
The full part number from the rating plate, a description of the fault and, if present, the data of the connected batteries.
📚 Further reading
👉 SITOP range · 👉 SITOP single-phase · 👉 SITOP three-phase and DC/DC
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
- Details
Siemens SITOP: three-phase power supplies and DC/DC converters (roots 6EP14, 6EP15, 6EP34)
For higher currents, SITOP power supplies with three-phase input (400 – 500 V AC) provide 24 V DC to large cabinets and machines. DC/DC converters, on the other hand, derive the control voltage from an existing DC voltage, for example from a drive bus.
The E-Repair catalogue covers about 26 part numbers from these families.
⚙️ Product lines in the catalogue
| Root | Content | Part numbers |
| 6EP1434 | Three-phase power supplies of about 10 A: PSU300S and SITOP POWER "Basic Line" | 6 |
| 6EP1436 | Three-phase power supplies of about 20 A: PSU300S, PSU300M, SITOP modular | 7 |
| 6EP1437 | Three-phase power supplies of about 40 A: PSU300S, PSU8200, SITOP modular | 8 |
| 6EP3436, 6EP3447 | Most recent generation: PSU6200, PSU8200 and PSU8600 | 4 |
| 6EP1536 | SITOP POWER 20 DC/DC converter, DC input | 1 |
👉 6EP1434-1SH01 – SITOP POWER 10, three-phase
👉 6EP1437-1SH01 – SITOP POWER 40, three-phase
👉 6EP3436-7SB00-3AX0 – SITOP PSU6200 24 V/20 A
👉 6EP1536-1SL01 – SITOP POWER 20 DC/DC converter
👉 Search the catalogue: 6EP143 · 6EP1536 · 6EP34
⚠️ Typical faults
- capacitors degraded after years of continuous operation
- input stages damaged by overvoltages or mains imbalance
- insufficient cabinet ventilation, with thermal protection trips
- output no longer able to sustain the rated current
🛠️ E-Repair services for three-phase and DC/DC SITOP power supplies
As Approved Partner Siemens – Industry Services, E-Repair supports production continuity:
🔧 Component-level repair in E-Repair's certified in-house laboratory, with diagnosis and repair where technically feasible.
♻️ Refurbishment with replacement of components subject to ageing and functional testing according to the agreed scope of work.
🚚 Advance replacement with a refurbished or new product, if available in stock and after a compatibility check.
🛠️ On-site and remote technical assistance for diagnosis and recommissioning.
✅ Standard 12-month warranty on the services for which it applies, extendable up to 24 months under the applicable conditions.
❓ Frequently asked questions
✔️ Can a 40 A three-phase power supply be repaired?
Yes, in most cases. For larger sizes repair is often more cost-effective than replacement.
✔️ Can I replace a SITOP POWER with a PSU8200?
Often yes, after checking input, output, dimensions and connections. Signalling functions may differ.
✔️ What is needed for the diagnosis?
The full part number from the rating plate and a description of the fault.
📚 Further reading
👉 SITOP range · 👉 SITOP single-phase · 👉 SITOP UPS and add-on modules
ℹ️ The information provided is general and indicative. Before purchase, installation or commissioning, check the data against the official Siemens documentation or contact E-Repair.
ES
DE
FR
IT 