Results list: 16007 products found in New or remanufactured

Brand Product ID Description Show Options
6SL3211-0KB15-5UA1 - SIEMENS SIEMENS SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C
BOX E-Repair SIEMENS SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C WITHOUT BOP WITHOUT ANALOG INPUT
6SL3211-0KB15-5UB1 - SIEMENS SIEMENS SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.55KW; VT: 0.55KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +50 DEG C
BOX E-Repair SIEMENS SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
6SL3211-0KB17-5BA1 - SIEMENS SIEMENS SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C
BOX E-Repair SIEMENS SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT ANALOG INPUT
6SL3211-0KB17-5BB1 - SIEMENS SIEMENS SINAMICS G110 - CPM110 AC-DRIVE,BUILT IN CL. B FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40
BOX E-Repair SIEMENS SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT RS485-INTERFACE
6SL3211-0KB17-5UA1 - SIEMENS SIEMENS SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ ANALOG INPUT CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C
BOX E-Repair SIEMENS SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C WITHOUT BOP WITHOUT ANALOG INPUT
6SL3211-0KB17-5UB1 - SIEMENS SIEMENS SINAMICS G110 - CPM110 AC-DRIVE, WITHOUT FILTER 1AC200-240V +10/-10% 47-63HZ RS485-INTERFACE (USS-PROTOCOL) CT: 0.75KW; VT: 0.75KW CT-OVERLOAD: 150% 60S 150 X 90 X 101 (HXWXD) IP20; WITH FLAT HEATSINK; COLDPLATE ASSEMBLY ONLY AMBIENT TEMP -10 TO +40 DEG C
BOX E-Repair SIEMENS SINAMICS G120X rated power: 45 kw at 110 % 60 s, 100 % 240 s radio interference filter for category c2 3ac 380-480 v+10/-20% 47-63 hz ambient temperature -20 ... +45 °c frame size : fse degree of protection ip20 / ul open type paint finish 3c2 with basic operator panel without io expansion integrated fieldbus: profinet pn, ethernet ip
6SL3223-0DE24-0BA0 - SIEMENS SIEMENS SINAMICS G120P POWER MODULE PM230 WITH BUILT IN CL. B FILTER PROTECTION IP55 / UL TYPE12 3AC380-480V +10/-10% 47-63HZ
6SL3223-0DE25-5AA1 - SIEMENS SIEMENS SINAMICS G120P POWER MODULE PM230 CON FILTRO INTEGRATO CL. A GRADO DI PROTEZ. IP55/UL TYPE12 3AC380-480V +10/-10% 47-63HZ POTENZA LOW OVERLOAD: 5,5KW CON 150% 3S,110% 57S,100% 240S TEMP. AMB. -10 TO +40 GRD C(LO) 540 X ...vedi note tecniche del prodotto
BOX E-Repair SIEMENS SINAMICS G120P Power Module PM230 with integrated Class B filter Degree of protection IP55/UL Type 12 380-480 V 3 AC +10/-10% 47-63 Hz Power low overload: 7.5kW at 150% 3s, 110% 57s, 100% 240 s; Ambient temperature 0 to +40 °C (LO) 540x 180x 249 (HxWxD), FSB without Control Unit and operating unit released for CU230P-2 Firmware version V4.3.2 or higher
Page 939 of 1068 (16007 items)
fas fa-times
Proyectos de Investigación e Innovación
  • Progetto Horizon 2020 – Digiprime
  • Progetto "E-Repair Digitale e Sostenibile" finanziato nel quadro del POR FESR Toscana 2021 -2027
  • Progetto "ICS 4.0" finanziato dal POR FESR Toscana 2014-2020
  • Progetto “Innovazione E-Repair” finanziato nel quadro del POR FESR Toscana 2014-2020
  • Operazione “E-REPAIR_2021” /Progetto Co-finanziato/Finanziato dal POR FESR Toscana 2014-2020
  • Progetto New E Repair 2015 finanziato nel quadro del POR FESR Toscana 2014-2020